Cable Analyzer Home   Cable Testers and Harness Testers Made Easy!

 

                Cable Testing Products        Support        Information Center        About Us        Contact Us

 

Signature Touch 1 ULTRA Specifications.

Capacity 128 to 256 points in 128-point increments
Low Voltage
Test Levels
Low Voltage & Current: 5 volts @ 6mA max current
Connection Resistance: .1 ohm to 100K ohm ±1%, ± .1ohm, also 500K, 1M, 5M
4-wire Resistance: .001 ohm to 1M ohm ±4%, ± .001 ohm.

High Voltage
Test Levels
High Voltage Tests Internal (Touch 1)
I.R:          50 to 1500VDC in 1 volt steps ±5% 5Mohm to 1000Mohm ±10%
DWV:       50 to 1500VDC / 1000VAC ±5% 0.1mA to 1.5mA leakage current threshold
Dwell:       DWV Dwell: 10 msec. to 120 sec.

High Voltage Tests External ( AR )
I.R:           1 to 1000VDC in 1 volt steps ±2% ±5V, 0.05Mohm to 50,000Mohm
DC DWV:   1 to 2800VDC ±2% ±5V, .4mA to 10mA leakage current threshold
AC DWV:   1 to 2000VAC ±2% ±5V, .001mA to 1.5mA leakage current threshold (Real)
                    .001mA to 30mA leakage current threshold (Total)

Dwell:        DWV Ramp: 0.1 to 999.9 sec.
                 DWV Dwell: 0.4 to 999.9 sec.
                 IR Ramp: 0.1 to 999.9 sec.
                 IR Dwell: 1 sec. to 999.9 sec.

Capacitance 5nF to 100µF ±10% ±.02nF    (relative measurements to 10pF)
Components Tested Resistors, diodes, capacitors, wires, 4-wire wire, 4-wire resistor and Link.
Test Rate Connection Test:   128 points/.25 second (typical)
Hipot Test: (internal):   10ms to 120 sec dwell per net:   High speed hipot test, user selectable on/off.
Hipot Test: (external):   (See Dwell Specs. to calculate test rate for external tests)
Max Capacitance Per Net DC
100VDC .6µF @ 500VDC,240nF, @1000VDC, 60nF, @1500VDC 27nF,
@2000VDC 15nF, @2500VDC 10nF
AC
100VAC 800nF, @500VAC, 120nF, @1000VAC, 30nF, @1500VAC 13nF,
@2000VAC 7.5nF

HV Energy Limit Current limited to 6mA for 10ms duration.
Controller Built-in Pentium-class PC with 1 floppy and 1 hard drive. Serial, parallel, keyboard, monitor, auxiliary digital I/O ports standard. Ethernet port optional.
Point Labeling User-definable labels of up to 30 characters, also custom file descriptions of up to 30 characters.
Power 105-135VAC 60Hz or 210-260VAC 50Hz - switchable
Dimensions: Base Assembly: 26"w x 21" d x 14" h (66cmx53cmx35cm)
Scanner Assembly: 26"w x 21" d x 10" h (66cmx53cmx26cm)
Weight Base Assembly: 105lbs. (48kgs.)
Scanner Assembly: 128 points 41lbs. (18.5kgs.) 256 points 54lbs. (24.5kgs.)
Display 3½" x 4½" Graphical Touch Screen
Warranty One year parts and labor.


Cirris Systems - Our Products - Testers - Signature Touch 1 Ultra - Specifications.
Toll-free 1-800-441-9910